This guide explains all Daikin Heat Pump error codes (CH series) with simple troubleshooting steps to help you identify and fix common issues safely before calling a technician.
U0
Low Refrigerant Level
- Check the system for refrigerant leaks.
- Inspect pressure levels using proper HVAC gauges.
- Repair and seal leaks before recharging.
- Call a certified technician for safe refrigerant handling.
U2
Power Supply Voltage Issue
- Check incoming voltage stability.
- Inspect circuit breakers and electrical wiring.
- Ensure correct power supply rating for the unit.
- Use a voltage stabilizer if fluctuations persist.
U4
Signal Transmission Error
- Inspect wiring between control boards.
- Check connectors for looseness or corrosion.
- Reset the system after inspection.
- Replace damaged communication cables if needed.
U5
Indoor/Outdoor Communication Error
- Verify connection between indoor and outdoor units.
- Inspect wiring for damage or disconnection.
- Restart both units to reset communication.
- Replace control board if the issue persists.
A1
Indoor PCB Failure
- Turn off power supply immediately.
- Inspect indoor control board connections.
- Check for burnt or damaged components.
- Replace PCB if malfunction continues.
A3
Drain System Malfunction
- Check drain hose for blockage.
- Clean condensate pan and drainage pipe.
- Ensure proper water flow through system.
- Remove any debris in drainage path.
A6
Fan Motor Error
- Inspect indoor fan motor for obstruction.
- Check wiring and electrical connectors.
- Clean dust buildup on fan blades.
- Replace motor if it fails to operate.
C4
Heat Exchanger Sensor Fault
- Check temperature sensor connection.
- Inspect sensor for corrosion or damage.
- Replace thermistor if readings are inaccurate.
- Secure wiring to ensure stable signal.
C7
Louver Motor Failure
- Check louver movement for obstruction.
- Inspect motor wiring and gear assembly.
- Reset system and test swing function.
- Replace motor if it does not respond.
E1
Outdoor PCB Failure
- Turn off power before inspection.
- Inspect outdoor control board connections.
- Check for burnt or damaged components.
- Replace PCB if fault continues.
E5
Compressor Overload
- Allow compressor to cool down.
- Check refrigerant charge and balance.
- Inspect condenser airflow for blockage.
- Call technician if overload persists.
E6
Compressor Startup Failure
- Check power supply stability.
- Inspect capacitor and wiring connections.
- Ensure compressor is not mechanically seized.
- Service unit if startup repeatedly fails.
E7
Outdoor Fan Motor Fault
- Check fan blades for obstruction.
- Inspect motor wiring connections.
- Clean dust and debris from fan assembly.
- Replace motor if defective.
E9
Electronic Expansion Valve Error
- Check valve control wiring.
- Inspect refrigerant flow system.
- Reset system and retest operation.
- Replace valve if malfunction persists.
F3
Discharge Temperature Abnormal
- Check refrigerant level and charge condition.
- Inspect compressor performance.
- Ensure proper airflow across condenser.
- Service system if overheating continues.
H6
Compressor Lock Protection
- Check compressor for mechanical seizure.
- Inspect capacitor and start components.
- Verify stable voltage supply.
- Replace compressor if locked.
P4
High Pressure Protection
- Clean condenser coils and filters.
- Check airflow obstruction.
- Inspect for refrigerant overcharge.
- Reduce system load and restart.
J3
Discharge Pipe Temperature Fault
- Check discharge temperature sensor.
- Inspect refrigerant flow and compressor load.
- Clean condenser coils.
- Service system if overheating persists.
DAI-HP21
Heating Mode Not Working
- Check heating mode is selected.
- Set temperature higher than room temperature.
- Clean air filters for better airflow.
- Inspect outdoor unit for ice or blockage.
DAI-HP22
Cooling Mode Not Working
- Confirm cooling mode is selected.
- Check thermostat settings.
- Clean filters and indoor unit.
- Inspect refrigerant level if performance is weak.
DAI-HP23
Unusual Noise From Heat Pump
- Check for loose panels or mounting issues.
- Clean fan blades and remove debris.
- Inspect outdoor unit obstruction.
- Call technician if compressor noise persists.
DAI-HP24
Heat Pump Turning Off Unexpectedly
- Check timers and thermostat settings.
- Inspect power supply and breaker.
- Clean filters to prevent overheating.
- Check for system error codes.
DAI-HP25
Water Leakage From Unit
- Check drain line for blockage.
- Inspect for ice buildup.
- Ensure proper installation and leveling.
- Clean air filters regularly.
DAI-HP26
Cold Air in Heating Mode
- Check defrost cycle operation.
- Ensure heating mode is active.
- Inspect outdoor unit frost buildup.
- Allow system time to stabilize.
DAI-HP27
Remote Control Not Responding
- Replace remote batteries.
- Check sensor alignment.
- Remove obstacles between remote and unit.
- Reset system if needed.
DAI-HP28
Outdoor Unit Frozen / Ice Build-Up
- Check defrost cycle operation.
- Ensure proper airflow around unit.
- Inspect outdoor unit for ice buildup.
- Call technician if freezing persists.
DAI-HP29
Low Efficiency Performance
- Clean or replace filters.
- Close doors and windows.
- Check correct unit sizing.
- Inspect refrigerant levels.
DAI-HP30
System Reset Procedure
- Turn off power or breaker.
- Wait 5–10 minutes.
- Restart system.
- Restore default settings if needed.